Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS300LRAA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS300LRAA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) brain of the ICP Tempstar/Heil RGS300LRAA0AAAA gas furnace. It sequences the entire heating cycle — energizing the inducer, proving pressure switches, firing the hot surface igniter, opening the gas valve, monitoring flame, and timing the blower on and off delays. It also reads thermostat calls and provides diagnostic fault codes via an onboard LED. A failed board causes intermittent or total no-heat, blower running constantly, no response to the thermostat, or repeated lockouts that no other component can explain.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC)
Brand ICP (Tempstar / Heil)
Fitment OEM
Application Gas Furnace Sequencing & Diagnostics

Compatibility

Supplied as the factory replacement control board kit for the ICP Tempstar/Heil RGS300LRAA0AAAA gas furnace, and fits matching RGS300 series furnaces using the same board. Verify the part number printed on your existing board and your unit's model/serial tag before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter before touching wiring.
  2. Access — Remove the furnace control/blower compartment access panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting; the harness positions are critical.
  4. Remove — Label and unplug each connector, remove the board mounting screws, and lift out the old control board.
  5. Install — Mount the new 1183618 board, transfer connections one at a time per your photos, and confirm the ground is secure.
  6. Test — Restore power, run a full heat cycle, and watch the diagnostic LED to confirm normal operation with no fault codes.

Signs You Need a Replacement

  • Furnace does not respond to thermostat calls for heat
  • Blower runs continuously or fails to start on schedule
  • Intermittent ignition lockouts with no fault in igniter, valve, or switches
  • Diagnostic LED is dark, scrambled, or flashing a hard board fault

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300LRAA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300LRAA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300LRAA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR