Overview

This is the genuine OEM control board kit (part number 1183618) for the ICP Tempstar Heil RGS300LFAA0AAAA gas furnace. The integrated furnace control board is the brain of the unit — it manages the ignition sequence, sequences the inducer and blower motors, monitors limit and pressure switches, controls gas valve timing, and runs the self-diagnostic flash codes. When the board fails, the furnace may show no response at the thermostat, run blower or inducer continuously, fail to ignite, or display erratic fault codes. This kit ships as a complete control assembly for a clean, direct replacement that restores full furnace operation and safety monitoring.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fits Model RGS300LFAA0AAAA
Application Gas Furnace Control
Fitment OEM Direct Replacement Kit

Compatibility

This control board kit is the factory-specified replacement for the ICP Tempstar Heil RGS300LFAA0AAAA furnace. Because ICP manufactures equipment under the Tempstar, Heil, Comfortmaker, and related badges, part 1183618 also services equivalent furnace models across those lines. Match the part number on your existing board before ordering to ensure correct fitment.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire and connector on the board before disconnecting; label harnesses if needed.
  4. Remove — Unplug all connectors, remove the mounting screws or standoffs, and lift out the old board.
  5. Install — Mount the new board on the same standoffs and reconnect every harness exactly as photographed.
  6. Test — Restore gas and power, run a full heat cycle, and confirm normal flash-code status, proper blower/inducer operation, and reliable ignition.

Signs You Need a Replacement

  • Furnace completely unresponsive to thermostat calls
  • Inducer or blower runs continuously or won't start
  • Erratic or no diagnostic flash codes from the board
  • Visible burn marks, corrosion, or failed relays on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee — if it doesn't fit, we make it right.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300LFAA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300LFAA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300LFAA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.