This genuine OEM control board kit (part number 1183618) fits the ICP / Tempstar / Heil RGS300LEAA0AAAA gas furnace. The integrated furnace control board is the brain of the unit — it manages the ignition sequence, sequences the inducer and blower, monitors safety limits and flame sensing, and times every heat and cool cycle. When the board fails from voltage surges, corrosion, burned relays, or cracked solder joints, the furnace may not respond to the thermostat, may lock out, or may behave erratically. This complete OEM kit replaces the board with the exact firmware and relay configuration your system requires.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Fits Model RGS300LEAA0AAAA
Fitment Genuine OEM

Compatibility

Direct-fit replacement for the ICP / Tempstar / Heil RGS300LEAA0AAAA and other RGS300 family furnaces specifying OEM control board kit 1183618. Match the board part number and connector layout to your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment service panel.
  3. Document — Photograph every wire harness and connector on the old board before disconnecting — this is critical for control boards.
  4. Remove — Unplug each connector, release the mounting standoffs or screws, and lift out the old board.
  5. Install — Mount the new board and reconnect every harness exactly per your photos; confirm any DIP switch or jumper settings match the original.
  6. Test — Restore power, run a full heat and cool cycle, and confirm the inducer, igniter, and blower sequence correctly with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive to the thermostat
  • No inducer, igniter, or blower activation on a heat call
  • Persistent fault/error code or continuous lockout
  • Visible burned relays, scorch marks, or corrosion on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300LEAA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300LEAA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300LEAA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.