Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS300LDAA0AAAA — OEM Part 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS300LDAA0AAAA — OEM Part 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the electronic brain of the ICP / Heil / Tempstar RGS300LDAA0AAAA gas furnace. It manages the entire heating sequence — reading the thermostat call, energizing the inducer, proving the pressure switch, firing the igniter, opening the gas valve, monitoring flame, and staging the blower on and off. It also runs the safety logic and reports fault codes via its diagnostic LED. When the board fails, the furnace may be completely dead, ignite erratically, blow cold air, or flash error codes that point nowhere. Replacing it with the correct OEM kit restores proper sequencing, safety supervision, and reliable heat.

Specifications

Spec Value
Part Number 1183618
Description Control Board Kit
Type Integrated Furnace Control (IFC)
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model RGS300LDAA0AAAA
Fitment Genuine OEM Replacement Kit

Compatibility

Direct-fit replacement kit for the ICP/Heil/Tempstar RGS300LDAA0AAAA gas furnace and shared platform models specifying OEM part 1183618. Confirm the part number on your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the furnace control/blower panel to expose the existing control board.
  3. Document — Photograph every connector, harness, and terminal position before disconnecting.
  4. Remove — Unplug the harnesses one at a time, release the mounting standoffs/screws, and lift out the old board.
  5. Install — Mount the new board, transfer each connector to its matching terminal per your photo, and confirm dip-switch/jumper settings match the original.
  6. Test — Restore power, run a full heat cycle, and verify the diagnostic LED shows normal operation with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive to a thermostat call.
  • Diagnostic LED flashing inconsistent or unresolvable fault codes.
  • Blower or inducer runs continuously, or won't run at all.
  • Visible burnt traces, scorched relays, or a melted connector on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300LDAA0AAAA — OEM Part 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300LDAA0AAAA — OEM Part 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300LDAA0AAAA — OEM Part 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.