This OEM control board kit (part 1183618) is the brain of your ICP / Tempstar / Heil RGS300HTFA0AAAA package unit. The integrated control manages the ignition sequence, inducer and blower timing, flame sensing, safety lockouts, and the 24V signals to the gas valve and relays. When the board fails, the symptoms range widely: no response on a call for heat, blower or inducer that won't start or won't stop, intermittent lockouts, or flashing diagnostic LED fault codes. Because the board ties every major function together, a failed control is a frequent cause of hard-to-diagnose, intermittent furnace problems. This kit ships with the correct OEM board for direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Control Voltage 24V
Function Ignition, blower & safety control

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar RGS300HTFA0AAAA model and related RGS-series units that specify this control kit. Verify the connector layout and part number against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment panel.
  3. Document — Photograph every plug, wire, and connector position before disconnecting — this is critical for a control board.
  4. Remove — Unplug each harness, release the board mounting standoffs/screws, and lift out the old board.
  5. Install — Mount the new board, then reconnect every harness to the matching connector per your photos.
  6. Test — Restore power, run a full heat and cool cycle, and confirm correct timing with no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a call for heat
  • Flashing diagnostic LED fault codes pointing to the control
  • Blower or inducer motor that won't start or won't shut off
  • Random lockouts or intermittent operation with no other failed component

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300HTFA0AAAA — Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300HTFA0AAAA — Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300HTFA0AAAA — Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.