Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS300HREA0AAAA — OEM Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS300HREA0AAAA — OEM Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The control board kit (OEM part 1183618) is the brain of your ICP RGS300HREA0AAAA gas furnace. This integrated furnace control sequences the entire heating and cooling cycle: it reads the thermostat call, runs the inducer and proves the pressure switch, energizes ignition, monitors flame rectification, and times the blower on and off. It also drives the cooling blower speed and reports diagnostic fault codes through its onboard LED. When the board fails, you see blank LEDs, no response to a call, blower-only operation with no ignition, or repeated soft lockouts that no other component explains. This kit ships with the mounting hardware and instructions needed for a clean swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar)
Control Voltage 24 VAC
Diagnostics Onboard LED Fault Codes
Fit OEM Direct Replacement Kit

Compatibility

Direct OEM replacement for the ICP/Heil/Tempstar RGS300HREA0AAAA and shared-platform gas furnaces using this integrated control. Verify the board part number and connector layout against your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power and gas, then verify zero voltage with a multimeter.
  2. Access — Remove the blower/control-compartment service panel.
  3. Document — Photograph every harness connector and the thermostat wiring before unplugging anything.
  4. Remove — Unplug each labeled connector, unscrew the board from its standoffs, and lift it out.
  5. Install — Mount the new board, transfer connectors one-for-one per your photos, and set any speed/timing jumpers to match.
  6. Test — Restore power and gas, run a full heat and cool cycle, and confirm the LED shows normal status with no fault codes.

Signs You Need a Replacement

  • No LED light and no response to a thermostat call.
  • Inducer or blower runs but ignition never sequences.
  • Random lockouts with no pressure, flame, or limit fault to explain them.
  • Burned, corroded, or relay-clicking spots visible on the board.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300HREA0AAAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300HREA0AAAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300HREA0AAAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online