Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS300HEEA0AAAA — Integrated Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS300HEEA0AAAA — Integrated Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM control board kit (part 1183618) for the ICP / Heil / Tempstar RGS300HEEA0AAAA gas furnace. The integrated furnace control board is the brain of the appliance: it manages the ignition sequence, monitors the flame-sense signal, sequences the inducer and blower motors, reads the 24V thermostat call, and runs the safety interlocks for the limit and pressure switches. Because every heating cycle routes through this board, a failure can show up as no heat, intermittent operation, blower or inducer that won't run, or repeated lockouts even when the igniter, gas valve, and switches all test good. This kit ships with the mounting hardware and instructions needed for a direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Control Voltage 24V thermostat circuit
Function Ignition, flame sense, blower and inducer sequencing, safety interlocks

Compatibility

Direct OEM replacement kit for the ICP/Heil/Tempstar RGS300HEEA0AAAA and related ICP-family furnaces that use this integrated control. Verify the board part number and connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel to expose the control board.
  3. Document — Photograph every connector and wire harness position before unplugging.
  4. Remove — Unplug each harness, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board from the kit, transfer each connector to match your photos, and seat all harnesses fully.
  6. Test — Restore power, call for heat, and verify a complete ignition, flame-proof, and blower cycle.

Signs You Need a Replacement

  • No heat with no fault despite good igniter, valve, and switches
  • Blower or inducer motor won't start or runs continuously
  • Random lockouts or error codes that clear on a power reset
  • Burnt traces, scorched relays, or a cracked board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300HEEA0AAAA — Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300HEEA0AAAA — Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300HEEA0AAAA — Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.