This OEM integrated furnace control board kit (part #1183618) is the electronic brain of the ICP/Heil/Tempstar RGS300HDAA0AAAA gas furnace. It manages the complete ignition sequence — inducer startup, hot surface igniter warm-up, gas valve timing, blower fan control, and continuous flame sensing and safety lockout. The board monitors limit switches and pressure switches and will shut the system down if it detects an unsafe condition. When this board fails, the furnace typically will not fire at all, short-cycles, or runs the blower continuously. It operates on a 24V control circuit and includes the diagnostic LED used to read fault codes.

Specifications

Spec Value
Part Number 1183618
Type Integrated Ignition Control Board Kit
Brand ICP / Heil / Tempstar
Control Voltage 24V
Fits Model RGS300HDAA0AAAA
Diagnostics On-board LED fault codes

Compatibility

Directly fits the ICP/Heil/Tempstar RGS300HDAA0AAAA gas furnace and shares the same control platform used across many ICP-family RGS series furnaces. Always confirm your existing board's part number and connector layout against 1183618 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every wire harness and connector position before disconnecting anything.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, then reconnect every harness exactly as photographed.
  6. Test — Restore power, initiate a heat call, and confirm a full ignition cycle and correct LED status.

Signs You Need a Replacement

  • Furnace will not ignite or has no response to a heat call
  • Blower runs constantly or never engages
  • Rapid short-cycling or repeated safety lockouts
  • Error LED flashing fault codes or no LED at all

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300HDAA0AAAA — Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300HDAA0AAAA — Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300HDAA0AAAA — Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.