Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS243LDFA0AAAA — Integrated Ignition Module | Ships Today
ICP

ICP Furnace Control Board Kit for RGS243LDFA0AAAA — Integrated Ignition Module | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part #1183618) is the integrated furnace control (IFC) — the brain of your ICP/Tempstar/Heil RGS243LDFA0AAAA gas furnace. It manages the entire heating sequence: it reads the thermostat call, runs ignition timing, sequences the inducer and blower motors, monitors the flame sensor and pressure switches, and provides safety lockout and diagnostic fault codes via its onboard LED. When this board fails, the furnace may be completely dead, short-cycle, run the blower continuously, or flash a fault code that won't clear. The kit ships with the mounting hardware and instructions needed for a clean replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower, Inducer & Safety Control
Diagnostics Onboard LED Fault Codes
Fitment OEM Direct Replacement

Compatibility

Supplied as a direct-fit replacement kit for the ICP/Tempstar/Heil RGS243LDFA0AAAA and other furnaces specifying OEM part 1183618. Verify the wiring harness plug layout matches your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph every connector and wire on the old board before disconnecting.
  4. Remove — Unplug each harness, release the board standoffs or screws, and lift out the old control.
  5. Install — Mount the new board with the included hardware and transfer each connector to its matching plug per your photo.
  6. Test — Restore power, call for heat, and confirm the full ignition-to-blower sequence runs with no fault codes.

Signs You Need a Replacement

  • Furnace completely dead with no response to the thermostat
  • Persistent or unclearable LED fault code
  • Blower or inducer runs continuously or never starts
  • Short-cycling or failure to complete the ignition sequence

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS243LDFA0AAAA — Integrated Ignition Module | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS243LDFA0AAAA — Integrated Ignition Module | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS243LDFA0AAAA — Integrated Ignition Module | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.