Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS240SFFA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS240SFFA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This ICP control board kit (OEM part #1183618) is the integrated furnace control (IFC) that manages your ICP/Heil/Tempstar RGS240SFFA0AAAA gas furnace. The board sequences the inducer, igniter, gas valve, and blower, monitors flame and pressure safeties, and stores diagnostic fault codes. When the board fails you may see a furnace that won't start, a blower that runs continuously, no response to the thermostat, or an LED flashing a hard fault. Replacing the control board restores proper ignition timing, safety supervision, and reliable heating operation.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board (Integrated Furnace Control)
Type Furnace Control Board
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model RGS240SFFA0AAAA
Fitment OEM Direct Replacement Kit

Compatibility

This control board kit is a direct OEM fit for the ICP/Heil/Tempstar RGS240SFFA0AAAA gas furnace and other RGS-series models that specify part 1183618. Confirm the board part number printed on your existing control before ordering, as furnace boards are model-specific.

Installation Guide

  1. Safety First — Disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower compartment service panel.
  3. Document — Photograph every wire and connector on the existing board, or transfer one wire at a time to avoid mistakes.
  4. Remove — Unplug the harness connectors, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, set any required jumpers/DIP switches to match the original, and reconnect each wire per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm correct inducer, ignition, gas, and blower sequencing with no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive to thermostat calls
  • Blower runs constantly or fails to start
  • Erratic ignition sequencing or random lockouts
  • Diagnostic LED dark, stuck on, or flashing a board/hard fault

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240SFFA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240SFFA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240SFFA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online