Overview

This OEM control board kit (part #1183618, KIT CONTROL BOARD) is the integrated furnace control that runs the entire heating sequence on your ICP Tempstar Heil RGS240SEFA0AAAA. The board manages the inducer, igniter, gas valve, blower timing, flame sensing, and all safety interlocks, coordinating each step from thermostat call to ignition to blower-off delay. It also reports fault codes through its diagnostic LED. When a board fails — from voltage surges, age, or moisture — you may see no response to a heat call, the blower running constantly, intermittent lockouts, or flashing error codes. Supplied as a complete kit, this replacement restores correct, safe sequencing and proper diagnostics.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Line Voltage 120 VAC
Diagnostics LED Fault Codes

Compatibility

Factory replacement control board kit for the ICP Tempstar Heil RGS240SEFA0AAAA and matched RGS240-series furnaces. Confirm the board's connector layout and part number against your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment panel.
  3. Document — Photograph every connector and the wiring diagram before disconnecting.
  4. Remove — Unplug the harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board and reconnect each harness to the matching plug per your photo.
  6. Test — Restore power, call for heat, and confirm the full sequence runs and the diagnostic LED shows normal operation.

Signs You Need a Replacement

  • No response to a heat call from the thermostat
  • Blower runs continuously or fails to start
  • Intermittent lockouts or random shutdowns
  • Diagnostic LED flashes a control-fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240SEFA0AAAA — Integrated Ignition | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240SEFA0AAAA — Integrated Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240SEFA0AAAA — Integrated Ignition | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online