Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS240LTFA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS240LTFA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The ICP control board kit (OEM part 1183618) is the integrated furnace control that manages your RGS240LTFA0AAAA gas furnace's entire heating sequence. It governs the inducer motor, igniter, gas valve timing, blower operation, and safety interlocks, while monitoring flame sense, limit switches, and pressure switches. A failed control board is one of the most common causes of a no-heat or short-cycling furnace. Symptoms include a furnace that won't start, blower that won't shut off, repeated lockouts, or diagnostic LED fault codes. This OEM kit includes the board and the hardware needed for a clean, direct replacement that restores correct sequencing and safety operation.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC)
Brand ICP (Tempstar / Heil / Comfortmaker)
Fits Model RGS240LTFA0AAAA
Fitment OEM Direct Replacement Kit
Application Gas Furnace Control

Compatibility

This control board kit is the OEM-specified replacement for the ICP RGS240LTFA0AAAA gas furnace and the equivalent Tempstar, Heil, and Comfortmaker models that call out ICP part 1183618. Confirm your furnace model number and the existing board part number before ordering, as control boards are model-series specific.

Installation Guide

  1. Safety First — Disconnect electrical power at the furnace switch or breaker and shut off the gas. Verify zero voltage with a multimeter before working in the control compartment.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every wire and connector on the existing board and note any factory jumper or dip-switch settings before disconnecting.
  4. Remove — Unplug all connectors, remove the board mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer any jumpers/dip-switch settings to match the original, and reconnect every harness exactly per your photos.
  6. Test — Restore gas and power, run a full heat cycle, and confirm correct ignition, blower, and shutdown sequencing with no fault codes.

Signs You Need a Replacement

  • Furnace won't power up or won't respond to a call for heat
  • Blower runs constantly or won't start
  • Repeated ignition lockouts with no other failed component
  • Diagnostic LED shows a control-fault code or no light at all

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240LTFA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240LTFA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240LTFA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online