Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS240LREA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS240LREA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM furnace control board kit (part number 1183618) is the integrated ignition control module for the ICP / Tempstar / Heil RGS240LREA0AAAA gas furnace. The board orchestrates the full heating sequence — energizing the inducer, sequencing the hot surface igniter, opening the gas valve, proving flame, and timing the blower on and off. It also enforces safety lockouts and reports diagnostic fault codes through an onboard LED. A failed board commonly causes a no-start furnace, repeated lockouts, a continuously running blower, or erratic short-cycling. Installing a genuine OEM replacement restores correct sequence-of-operation and safety control.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated Furnace Ignition Control Board
Brand ICP / Tempstar / Heil
Fits Model RGS240LREA0AAAA
Application Gas Furnace
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP / Tempstar / Heil RGS240LREA0AAAA gas furnace. Confirm the part number printed on your existing board matches 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire harness and connector position before disconnecting.
  4. Remove — Unplug all harnesses and pin connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, reconnect each harness exactly per your photo, and match any jumper/dip settings.
  6. Test — Restore power and run a full heat cycle; confirm ignition, flame sense, and blower timing with no fault codes.

Signs You Need a Replacement

  • Furnace will not ignite or repeatedly trips into lockout.
  • Blower runs continuously or never starts.
  • No diagnostic LED or a steady fault-code flash.
  • Burn marks, corrosion, or cracked traces visible on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240LREA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240LREA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240LREA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online