This OEM control board kit (part number 1183618) is the electronic brain of the ICP/Tempstar/Heil RGS240LEFA0AAAA furnace. It manages the entire heating sequence — inducer start, pressure switch proving, igniter warm-up, gas valve timing, blower on/off delays, and safety lockouts — while monitoring the limit and flame-sensing circuits. Control boards fail from voltage surges, relay wear, cracked solder joints, and burnt connectors. Symptoms of a failing board include the furnace not responding to a call for heat, the blower or inducer running continuously, erratic or out-of-sequence operation, and diagnostic LED fault codes that point to a board fault.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Application Gas Furnace Ignition & Blower Control
Fitment Direct OEM Replacement Kit

Compatibility

Supplied as a direct OEM replacement kit for the ICP/Tempstar/Heil furnace model RGS240LEFA0AAAA. As a factory kit it includes the mounting and connection hardware needed for a clean swap. Verify the connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect electrical power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph every plug, terminal, and wire color on the old board before disconnecting anything.
  4. Remove — Unplug all harness connectors and remove the board mounting screws.
  5. Install — Mount the new board and reconnect each connector exactly per your photo and the wiring diagram.
  6. Test — Restore power, call for heat, and confirm a full, correct ignition and blower sequence with no fault codes.

Signs You Need a Replacement

  • Furnace does not respond to a call for heat.
  • Blower or inducer motor runs continuously and won't shut off.
  • Erratic, out-of-sequence, or short-cycling operation.
  • Diagnostic LED flashes a control-board or hard-lockout fault code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240LEFA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240LEFA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240LEFA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.