Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS240HTAA0AAAA - OEM | Ships Today
ICP

ICP Furnace Control Board Kit for RGS240HTAA0AAAA - OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) brain of your ICP / Tempstar / Heil RGS240HTAA0AAAA gas furnace. It manages the complete heating sequence: it powers the inducer, proves the pressure switch, energizes the hot surface igniter, opens the gas valve, monitors flame, and times the blower on and off. It also runs continuous self-diagnostics and flashes fault codes through its onboard LED. When the board fails, the furnace may be completely dead, stuck in lockout, short-cycle, or run the blower nonstop. Supplied as a complete kit with the mounting hardware and instructions needed for a clean swap, this OEM board restores full, code-correct furnace operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated furnace control board kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Function Ignition, gas valve, blower & diagnostics
Includes Board, mounting hardware, instructions
Fitment OEM exact replacement kit

Compatibility

Supplied as the factory control board kit for the ICP / Tempstar / Heil RGS240HTAA0AAAA gas furnace and shared across related ICP-family furnace platforms. Confirm the printed part number 1183618 and the connector layout on your existing board before ordering.

Installation Guide

  1. Safety First - Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access - Remove the furnace control/blower panel to expose the board.
  3. Document - Photograph every harness plug and wire location before disconnecting; boards have many similar connectors.
  4. Remove - Unplug each harness, release the standoffs/screws, and lift out the old board.
  5. Install - Mount the new OEM board with the supplied hardware and reconnect every plug exactly per your photos.
  6. Test - Restore power and run a full heat cycle, confirming a normal status LED and no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no status LED.
  • Repeated lockouts or error codes not traced to other components.
  • Blower runs continuously or fails to start.
  • Visible burn marks, scorched traces, or relay damage on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240HTAA0AAAA - OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240HTAA0AAAA - OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240HTAA0AAAA - OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online