Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS240HSFA0AAAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS240HSFA0AAAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM control board kit (OEM 1183618) for the ICP / Tempstar / Heil RGS240HSFA0AAAA. The integrated furnace control board is the brain of the unit — it sequences the inducer, hot surface igniter, gas valve, and blower, monitors the safety circuit (limits, pressure switch, flame sense), and manages timing and lockouts. Supplied as a kit with the mounting hardware and connectors needed for a direct replacement. When the board fails, symptoms range from no operation at all to erratic cycling, blower or inducer faults, and diagnostic LED error codes.

Specifications

Spec Value
OEM Part Number 1183618 (Kit, Control Board)
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower & Safety Sequencing
Includes Board, mounting hardware, connectors

Compatibility

Engineered for the ICP RGS240HSFA0AAAA and used across many ICP-family packaged and furnace platforms branded Tempstar, Heil, Comfortmaker, and Arcoaire. Match the OEM kit number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the control compartment panel.
  3. Document — Photograph every harness and plug position before disconnecting.
  4. Remove — Unplug each connector, release the standoffs/screws, and lift out the old board.
  5. Install — Mount the new board with the supplied hardware and reconnect every plug exactly per your photo.
  6. Test — Restore power and run a full heat and cool cycle, watching the diagnostic LED for normal operation.

Signs You Need a Replacement

  • Unit completely dead with 24V present at the board
  • Blower or inducer runs continuously or not at all
  • Fault/error codes flashing on the board's diagnostic LED
  • Burnt traces, scorched relays, or visible board damage

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240HSFA0AAAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240HSFA0AAAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240HSFA0AAAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera