Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS240HRFA0AAAA — Ships Today
ICP

ICP Furnace Control Board Kit for RGS240HRFA0AAAA — Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the integrated furnace control (IFC) brain of your ICP / Tempstar / Heil RGS240HRFA0AAAA gas furnace. It manages the entire heat cycle: it reads the thermostat call, sequences the inducer, energizes the hot surface igniter, opens the gas valve, monitors flame sense and safety limits, and times the blower on and off. When the board fails, the furnace may be completely dead, stuck in lockout, short-cycling, or running the blower continuously. A blinking diagnostic LED fault code, burnt or corroded relays on the board, and a furnace that ignores the thermostat are the classic symptoms. This kit ships with the mounting hardware and connectors needed for a clean OEM replacement that restores full, code-compliant operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Line Voltage 120V
Application Gas Furnace Sequencing & Safety

Compatibility

OEM kit for the ICP RGS240HRFA0AAAA furnace and related Tempstar, Heil, Comfortmaker, and Arcoaire RGS-series furnaces using the same integrated control. Confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph every harness plug and terminal on the old board before disconnecting.
  4. Remove — Unplug all connectors, release the board standoffs/screws, and lift the old board out.
  5. Install — Mount the new board and transfer each connector exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm the diagnostic LED shows normal operation.

Signs You Need a Replacement

  • Furnace completely dead or stuck in hard lockout.
  • Diagnostic LED flashing a fault / error code.
  • Blower runs constantly or won't start at all.
  • Burnt, corroded, or clicking relays on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240HRFA0AAAA — Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240HRFA0AAAA — Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240HRFA0AAAA — Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online