Overview

This OEM control board kit (part 1183618) is the integrated furnace control (IFC) brain of the ICP RGS240HREA0AAAA. It manages the entire heating sequence — inducer start, pressure switch proving, igniter warm-up, gas valve timing, flame sensing, and blower on/off delays — while running self-diagnostics and flashing fault codes through its onboard LED. When the board fails, symptoms range from a completely dead furnace to erratic short cycling, no inducer or blower operation, or ignition lockouts with no apparent cause. Burned relays, scorched traces, swollen capacitors, or a blank diagnostic LED point directly to a failed board.

Specifications

Spec Value
OEM Part Number 1183618 (Kit, Control Board)
Type Integrated Furnace Control (IFC)
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Application Gas Furnace Ignition & Blower Control
Fit OEM Direct Replacement Kit

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS240HREA0AAAA furnace and related RGS240 chassis variants. Verify the board part number printed on your existing board against the model and serial label before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment panel.
  3. Document — Photograph every plug and wire on the existing board before disconnecting — connectors are keyed but labeling speeds reassembly.
  4. Remove — Unplug each harness, release the standoffs or screws, and lift out the old board.
  5. Install — Mount the new board, transfer the dip-switch/jumper settings to match the original, and reconnect every harness per your photo.
  6. Test — Restore power and run a full heat cycle, confirming the diagnostic LED shows normal operation with no fault codes.

Signs You Need a Replacement

  • Furnace completely dead with power present
  • No inducer, igniter, or blower response on a heat call
  • Random short cycling or unexplained lockouts
  • Visible burn marks, swollen capacitors, or a blank diagnostic LED

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240HREA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240HREA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240HREA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.