Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS240HFAA0AAAA — OEM | Ships Today
ICP

ICP Furnace Control Board Kit for RGS240HFAA0AAAA — OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (1183618) is the integrated furnace control (IFC) brain of your ICP / Tempstar / Heil RGS240HFAA0AAAA gas furnace. It manages the entire heating sequence — inducer operation, igniter timing, gas valve activation, flame sensing, blower on/off delays, and safety lockouts. Supplied as a complete kit with the hardware needed for a clean swap. When the board fails, you'll see no response to thermostat calls, blowers that won't start or won't stop, repeated lockouts, or error/flash codes on the board's diagnostic LED. A new control board restores correct sequencing and protects every component it drives.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower & Safety Sequencing
Fitment OEM Direct Replacement Kit

Compatibility

Designed for the ICP/Tempstar/Heil RGS240HFAA0AAAA and related RGS-series furnaces. Confirm the OEM number on your existing board before ordering to ensure the kit matches.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment panel.
  3. Document — Photograph every plug and terminal on the old board before disconnecting.
  4. Remove — Unplug each connector, release the standoffs/screws, and lift out the failed board.
  5. Install — Mount the new board from the kit and reconnect every harness exactly as photographed.
  6. Test — Restore power, run a full heat cycle, and confirm igniter, gas valve, and blower sequence correctly with no fault codes.

Signs You Need a Replacement

  • Furnace unresponsive to thermostat heat calls
  • Blower runs constantly or fails to start
  • Repeated ignition lockouts or error flash codes on the board LED
  • Visible burn marks, corrosion, or damaged relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240HFAA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240HFAA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240HFAA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online