Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS214LFAA0AAAA — OEM | Ships Today
ICP

ICP Furnace Control Board Kit for RGS214LFAA0AAAA — OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board kit (part number 1183618) is the brain of your ICP RGS214LFAA0AAAA furnace. It manages the entire heating sequence — igniter timing, gas valve operation, inducer and blower control, flame sensing, and built-in safety lockouts. When the board fails, the furnace can refuse to start, lock out on a fault code, run the blower continuously, or short-cycle unpredictably. Power surges, failed relays, cracked solder joints, and corroded connectors are the usual culprits. This complete kit includes the mounting hardware and connectors needed for a clean swap. Always note any flashing diagnostic LED fault code before replacing the board, since the same symptom can stem from a bad igniter, pressure switch, or flame sensor.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Application Gas Furnace Ignition & Blower Control
Fitment OEM Direct Replacement Kit

Compatibility

Direct OEM replacement kit for the ICP / Tempstar / Heil RGS214LFAA0AAAA furnace. Control board kit 1183618 is used across the matching ICP-family furnace lineup (Tempstar, Heil, Comfortmaker). Verify the OEM part number against the board currently installed before ordering, as control boards are model-sequence specific.

Installation Guide

  1. Safety First — Disconnect electrical power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel.
  3. Document — Photograph every plug, terminal, and wire color on the board before disconnecting.
  4. Remove — Unplug each connector, release the mounting standoffs or screws, and lift out the old board.
  5. Install — Mount the new board on its standoffs and reconnect every harness exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm correct ignition, blower, and shutdown sequencing with no fault codes.

Signs You Need a Replacement

  • Furnace dead with no diagnostic LED or stuck on a hard-lockout code
  • Blower runs continuously or won't start at all
  • Random short-cycling not traced to igniter, sensor, or switch
  • Visible burn marks, swollen relays, or cracked solder on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS214LFAA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS214LFAA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS214LFAA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online