Overview

This OEM control board kit (part #1183618) is the brain of the ICP / Tempstar / Heil RGS214LEAA0AAAA furnace. It manages the entire heating sequence — inducer startup, igniter warm-up, gas valve timing, flame sensing, and blower fan control — while monitoring safety limits and pressure switches. When the board fails, the furnace may short cycle, fail to ignite, leave the blower running constantly, or flash diagnostic fault codes. Sold as a complete kit, it ships with the mounting hardware and instructions needed for a clean swap, restoring proper ignition timing and safe, reliable operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Application Gas Furnace Ignition & Blower Control

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil RGS214LEAA0AAAA and related RGS214 series gas furnaces. Confirm the part number against your existing board before ordering, as control boards are model-specific. The kit replaces the original integrated furnace control.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment door.
  3. Document — Photograph every wire harness and connector position on the old board before unplugging anything.
  4. Remove — Unplug each connector, release the mounting standoffs or screws, and lift out the old board.
  5. Install — Mount the new board on the same standoffs and reconnect every harness to its matching terminal per your photos.
  6. Test — Restore gas and power, run a full heat cycle, and confirm correct ignition, flame sensing, and blower timing with no fault codes.

Signs You Need a Replacement

  • Furnace short cycles or will not begin the ignition sequence
  • Blower runs continuously or never starts
  • Diagnostic LED flashes a hard-fault or board failure code
  • Intermittent or no response to thermostat heat calls

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS214LEAA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS214LEAA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS214LEAA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.