Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS214HRAA0AAAA — Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS214HRAA0AAAA — Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board kit, part 1183618, is the brain of the ICP / Heil / Tempstar RGS214HRAA0AAAA gas furnace. It manages the entire heating sequence — igniter timing, gas valve operation, inducer and blower motor staging, safety interlocks, and the diagnostic LED fault codes. Supplied as a complete kit with the necessary mounting hardware and instructions. Control boards typically fail from heat stress, power surges, or corroded relays, leaving the furnace dead, stuck in lockout, or running the blower continuously.

Specifications

Spec Value
Part Number 1183618
Type Integrated furnace control board (kit)
Brand ICP / Heil / Tempstar
Line Voltage 120V
Control Voltage 24V
Function Ignition, blower, and safety sequencing

Compatibility

Engineered for the ICP/Heil/Tempstar RGS214HRAA0AAAA furnace and shared-platform units from Comfortmaker, Day & Night, and Arcoaire. Always confirm the board's connector layout and part number against your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every wire harness and connector position on the old board.
  4. Remove — Unplug all connectors, release the mounting standoffs, and lift out the failed board.
  5. Install — Mount the new board on the standoffs and transfer each connector to match your photo exactly.
  6. Test — Restore power and run a full heat cycle; confirm the diagnostic LED shows a normal status code.

Signs You Need a Replacement

  • Furnace completely unresponsive to a call for heat
  • Blower or inducer runs constantly or not at all
  • Flashing diagnostic fault codes pointing to the control
  • Burnt smell, scorch marks, or charred relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS214HRAA0AAAA — Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS214HRAA0AAAA — Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS214HRAA0AAAA — Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera