Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS213SRCA0AAAA | Ships Today
ICP

ICP Furnace Control Board Kit for RGS213SRCA0AAAA | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part #1183618) is the integrated furnace control (IFC) — the brain of your ICP/Tempstar/Heil RGS213SRCA0AAAA furnace. It manages the ignition sequence, blower and inducer timing, safety interlocks (limit switch, pressure switch, flame sensing), and the thermostat interface. When the board fails, the furnace can show erratic behavior: no response to the thermostat, blower or inducer that won't start or won't stop, ignition lockouts with no obvious cause, or a flashing diagnostic LED fault code. Shipped as a kit with the necessary mounting hardware and instructions.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Application Gas Furnace Control

Compatibility

Direct OEM replacement for the ICP RGS213SRCA0AAAA and matching Tempstar, Heil, and Comfortmaker furnaces using the 1183618 control board kit. Verify the board's connector layout and part number against your existing control.

Installation Guide

  1. Safety First — Shut off gas and power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/service panel.
  3. Document — Photograph every wiring harness and connector on the old board before unplugging anything.
  4. Remove — Disconnect each labeled connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, then reconnect each harness to its matching terminal exactly per your photos.
  6. Test — Restore gas and power, run a full heat cycle, and confirm proper ignition, blower, and inducer operation with no fault codes.

Signs You Need a Replacement

  • Furnace unresponsive to the thermostat
  • Blower or inducer won't start or won't shut off
  • Random ignition lockouts with no failed component
  • Diagnostic LED flashing a control-fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213SRCA0AAAA | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213SRCA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213SRCA0AAAA | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online