Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS213SFEA0AAAA — Integrated Ignition | Ships Today
ICP

ICP Furnace Control Board Kit for RGS213SFEA0AAAA — Integrated Ignition | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM control board kit (part #1183618) for the ICP/Tempstar/Heil RGS213SFEA0AAAA gas furnace. The integrated furnace control (IFC) board is the brain of the furnace: it manages the ignition sequence, the inducer and blower motor timing, safety lockouts, flame sensing feedback, and communication with the thermostat. When the board fails, the furnace may not respond to a heat call, the blower may run constantly or not at all, or the unit may throw error codes via the diagnostic LED. This factory kit includes the board and mounting hardware for a complete, reliable replacement. Because the board governs every safety interlock, an OEM-matched control is strongly recommended over generic substitutes.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control (IFC) Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower & Safety Sequencing
Supply 120V Line Voltage
Fit OEM Exact Replacement Kit

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS213SFEA0AAAA and related ICP-family furnaces using the same integrated control platform. Match the board's part number and connector layout to your existing control before installing.

Installation Guide

  1. Safety First — Switch off furnace power and verify zero voltage at the board with a multimeter.
  2. Access — Remove the furnace control-compartment panel.
  3. Document — Photograph every connector and wire location on the old board before removal.
  4. Remove — Unplug each harness, release the board standoffs, and lift out the old control.
  5. Install — Mount the new board on the standoffs and reconnect every harness exactly per your photo.
  6. Test — Restore power, call for heat, and verify the full ignition-to-blower sequence runs without fault codes.

Signs You Need a Replacement

  • Furnace does not respond to a heat call
  • Blower runs constantly or never engages
  • Diagnostic LED flashing a board fault code
  • Intermittent operation or random lockouts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213SFEA0AAAA — Integrated Ignition | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213SFEA0AAAA — Integrated Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213SFEA0AAAA — Integrated Ignition | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online