Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS213HSAA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS213HSAA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM control board kit, ICP part number 1183618, for ICP/Tempstar/Heil RGS-series gas furnaces. The integrated furnace control board is the brain of the unit — it manages the ignition sequence, blower and inducer timing, safety interlocks (limits, pressure switch, flame sensing), and diagnostic fault codes. When the board fails you may see no response to a call for heat, the blower or inducer running continuously or not at all, erratic cycling, or flashing diagnostic codes. This kit includes the replacement board so you can restore full furnace operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated furnace control board kit
Brand ICP / Tempstar / Heil
Application Gas furnace ignition & blower control
Fit OEM

Compatibility

Fits ICP/Tempstar/Heil RGS213HSAA0AAAA and related RGS-series gas furnaces using control board kit 1183618. Verify the original board part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel to reach the control board.
  3. Document — Photograph every wire and connector position on the old board before disconnecting.
  4. Remove — Unplug the harness connectors and unscrew the failed board from its standoffs.
  5. Install — Mount the new board and reconnect each connector exactly per your photo.
  6. Test — Restore power, call for heat, and verify the full ignition and blower sequence with no fault codes.

Signs You Need a Replacement

  • No response to a thermostat call for heat
  • Blower or inducer runs constantly or not at all
  • Flashing diagnostic fault/error codes on the board LED
  • Visible burnt traces, scorch marks, or a failed onboard fuse/relay

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213HSAA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213HSAA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213HSAA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.