Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS213HREA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS213HREA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine ICP/Tempstar/Heil OEM control board kit (part 1183618) is the integrated furnace control (IFC) that manages the entire heating sequence on the RGS213HREA0AAAA. The board reads the thermostat call, runs the inducer and pressure-switch proving sequence, energizes the igniter, opens the gas valve, monitors flame via the sensor, and times the blower on and off delays. It also provides diagnostic LED fault codes and self-protection lockouts. Because the control board is the brain of the furnace, a failed board can cause no-heat, no blower, erratic cycling, or a furnace that ignites but won't stay running. This kit ships with the OEM board and the hardware needed for a direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Application Gas Furnace
Fit OEM

Compatibility

Engineered for the ICP/Tempstar/Heil RGS213HREA0AAAA and supplied as the OEM-specified replacement control for that platform. Confirm the part number 1183618 against your existing board, as integrated furnace controls are model- and revision-specific.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment panel.
  3. Document — Photograph every connector, wire, and terminal on the old board before disconnecting — wiring placement is critical.
  4. Remove — Unplug all connectors, remove the board's mounting screws/standoffs, and lift out the old control.
  5. Install — Mount the new 1183618 board and reconnect each plug and wire exactly per your photo, confirming the line-voltage polarity.
  6. Test — Restore power, run a full heat cycle, and verify ignition, flame proving, blower timing, and clean LED status with no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a heat call (no inducer, no igniter).
  • Blower runs continuously or never starts despite proper timing.
  • Diagnostic LED is dark, or flashes a hard internal/control fault.
  • Burnt spots, scorched relays, or corroded traces visible on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213HREA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213HREA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213HREA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.