This OEM control board kit, ICP part number 1183618, is the integrated furnace control (IFC) for the ICP, Tempstar, and Heil RGS213HRCA0AAAA gas furnace. The control board is the brain of the furnace: it manages the ignition sequence, sequences the inducer, igniter, gas valve, and blower, monitors safety inputs such as the flame sensor and pressure switch, and reports fault codes through its diagnostic LED. Boards fail from voltage surges, heat, corroded relays, and cracked solder joints — symptoms range from a completely dead furnace to short-cycling, no blower, no ignition, or repeating flash codes that don't correspond to a sensor fault. Supplied as a kit for a direct OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated furnace control board kit
Brand ICP / Tempstar / Heil
Application Gas furnace control
Fit OEM Replacement

Compatibility

Designed for the ICP/Tempstar/Heil RGS213HRCA0AAAA gas furnace. Always match the original board's part number and connector layout — control boards are model-specific. Confirm 1183618 against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment service panel.
  3. Document — Photograph every plug, harness, and terminal on the old board before disconnecting anything.
  4. Remove — Unplug each connector, release the board standoffs or screws, and lift out the failed board.
  5. Install — Mount the new board, then reconnect every harness to the matching terminal exactly per your photo. Verify any onboard DIP switch or jumper settings match the original.
  6. Test — Restore power and run a full heat cycle; confirm correct ignition sequencing, blower operation, and a steady (no-fault) diagnostic LED.

Signs You Need a Replacement

  • Furnace completely dead with no response to a heat call.
  • No ignition or no blower despite good sensors and valve.
  • Short-cycling or random lockouts with no matching sensor fault.
  • Visible burn marks, corroded relays, or cracked solder on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213HRCA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213HRCA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213HRCA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.