Overview

This is a genuine ICP / Tempstar / Heil control board kit, OEM part number 1183618, for the gas furnace model RGS213HFEA0AAAA. The integrated furnace control board is the brain of the system: it sequences the inducer motor, ignitor, gas valve, and blower, monitors safety limits and flame sense, and stores diagnostic fault codes. When the board fails you may see no response on a call for heat, blower or inducer that runs continuously, erratic cycling, or flashing fault codes that don't clear. The kit includes the board and the hardware needed to drop it into place. Because the board orchestrates every safety and timing function, a confirmed board failure should always be replaced with the correct OEM part.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Application Gas furnace ignition & blower control
Fits Model RGS213HFEA0AAAA

Compatibility

Designed for the ICP / Tempstar / Heil model RGS213HFEA0AAAA and other furnaces in the same platform that use control board kit 1183618. Confirm the OEM part number on your existing board before ordering, as control boards are model- and revision-specific.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter; shut off gas at the valve.
  2. Access — Remove the furnace control compartment panel.
  3. Document — Photograph every wire harness and terminal on the old board before disconnecting; note the board's dip-switch or jumper settings.
  4. Remove — Unplug each connector, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board, transfer any settings to match the original, and reconnect every harness per your photo.
  6. Test — Restore gas and power and verify a full heat cycle: inducer, ignition, flame proof, and blower all sequence correctly with no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a call for heat
  • Blower or inducer that runs continuously or won't start
  • Persistent or nonsensical fault-code flashes
  • Visible scorching, burnt relays, or corrosion on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213HFEA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213HFEA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213HFEA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.