Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS213HDEA0AAAA — Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS213HDEA0AAAA — Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control (IFC) that orchestrates the entire heating sequence on ICP / Heil / Tempstar gas furnaces. It manages the inducer, ignition, gas valve, and blower timing; reads the thermostat, pressure switch, limit, and flame-sense inputs; and runs onboard safety logic and self-diagnostics, flashing fault codes through its LED. When the board fails, the furnace can be completely dead, stuck on the inducer, fail to ignite, short-cycle, or run the blower continuously. Supplied as a kit with the hardware needed for a clean swap, this board restores correct ignition sequencing, safety monitoring, and diagnostic reporting. It is the brain of the furnace — replacing a failed board brings the whole appliance back to spec.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Function Ignition, blower, inducer & safety control
Diagnostics Onboard LED fault codes
Fitment OEM

Compatibility

Engineered for the ICP / Heil / Tempstar / Comfortmaker RGS213HDEA0AAAA gas furnace and related RGS-series models that use this integrated control. Match the existing board's part number 1183618 and connector layout before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment service panel.
  3. Document — Photograph every connector, plug, and wire position on the existing board before unplugging anything.
  4. Remove — Unplug each harness, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board, reconnect each harness to its matching connector per your photo, and confirm dip-switch/jumper settings match the original.
  6. Test — Restore power and run a full heat cycle, verifying inducer, ignition, gas valve, and blower sequence and a normal LED status.

Signs You Need a Replacement

  • Furnace completely dead with no LED activity.
  • No ignition or stuck inducer despite a heat call.
  • Continuous blower operation or persistent short-cycling.
  • Error/fault LED codes pointing to control failure.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213HDEA0AAAA — Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213HDEA0AAAA — Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213HDEA0AAAA — Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online