Overview

This OEM control board kit, ICP part number 1183618, is the integrated furnace control (IFC) that manages the entire heating sequence on your ICP, Heil, or Tempstar RGS213HDAA0AAAA gas furnace. The board orchestrates the inducer, ignition, gas valve, and blower timing while monitoring safety inputs such as the limit switch, pressure switch, and flame sensor. It is the brain of the furnace — when it fails, you may see no response to a heat call, a furnace stuck in lockout, blower or inducer that won't run, or erratic LED diagnostic fault codes. Supplied as a kit for a complete, reliable replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Control Voltage 24 VAC
Application Gas Furnace Sequence & Safety Control
Fit OEM Direct Replacement Kit

Compatibility

Direct OEM replacement kit for the ICP/Heil/Tempstar/Comfortmaker RGS213HDAA0AAAA gas furnace and related ICP-family units that specify the 1183618 control board kit. Verify the part number against your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph every wire harness and terminal on the old board before disconnecting; note any DIP switch or jumper settings.
  4. Remove — Unplug the connectors, remove the mounting screws or standoffs, and lift out the failed board.
  5. Install — Mount the new board, transfer any settings, and reconnect each harness exactly per your photos.
  6. Test — Restore power, call for heat, and verify a full ignition sequence with correct blower timing and no fault codes.

Signs You Need a Replacement

  • No response to a thermostat heat call
  • Furnace stuck in lockout or flashing error codes
  • Inducer or blower fails to energize on demand
  • Visible burn marks, corrosion, or a failed onboard fuse/relay

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS213HDAA0AAAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS213HDAA0AAAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS213HDAA0AAAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.