Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control for the ICP/Tempstar/Heil RGS210SSAA0AAAA. The board is the brain of the furnace: it manages the ignition sequence, sequences the inducer and blower, monitors the limit and pressure switches and flame sensor, controls the gas valve, and flashes diagnostic fault codes through its LED. Supplied as a kit, it includes the board and the hardware needed to retrofit it to the unit. A failed control board can cause no-heat conditions, a furnace that will not respond to the thermostat, blower or inducer faults, or erratic short cycling. Before condemning the board, confirm incoming 24V power and rule out a tripped limit, bad pressure switch, or weak ignitor — but a board with burned traces, a blown fuse that keeps reblowing, or no diagnostic LED is a clear replacement.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Includes Board + Mounting Hardware

Compatibility

Built for the ICP/Tempstar/Heil RGS210SSAA0AAAA furnace and related RGS-series units that specify the 1183618 control board kit. Verify the part number and connector layout against your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower access panel.
  3. Document — Photograph every connector and wire harness on the old board before unplugging.
  4. Remove — Unplug each harness, then unscrew the old board from its standoffs.
  5. Install — Mount the new board on the standoffs and reconnect each harness exactly per your photos.
  6. Test — Restore power and run a full heat cycle, confirming a clean ignition sequence and a steady diagnostic LED.

Signs You Need a Replacement

  • Furnace does not respond to the thermostat
  • No diagnostic LED or a repeating fault code
  • Inducer or blower will not run despite a valid call
  • Board fuse repeatedly blows or traces are visibly burned

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210SSAA0AAAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210SSAA0AAAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210SSAA0AAAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.