Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS210SRCA0AAAA — OEM | Ships Today
ICP

ICP Furnace Control Board Kit for RGS210SRCA0AAAA — OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM control board kit (part #1183618) for the ICP/Heil/Tempstar RGS210SRCA0AAAA gas furnace. The integrated furnace control board is the brain of the furnace — it manages the ignition sequence, monitors safety inputs (limits, pressure switch, flame sense), and times the inducer and blower on heat and cool calls. The kit includes the board and required mounting/connection hardware for a complete replacement. A failed board is the usual culprit when a furnace is completely dead, won't sequence, blows error codes, or has no blower operation despite good power and a working thermostat.

Specifications

Spec Value
Part Number 1183618
Type Integrated furnace control board kit
Brand ICP / Heil / Tempstar
Application Gas furnace ignition & blower control

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar RGS210SRCA0AAAA and related RGS210 family furnaces that specify kit #1183618. Always match the OEM part number on your existing board before ordering, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect electrical power and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every connector and wire on the board before unplugging anything.
  4. Remove — Unplug the harnesses, release the board from its standoffs, and remove it.
  5. Install — Mount the new board, transfer each connector to the matching terminal per your photo, and set any jumpers/dip switches to match the original.
  6. Test — Restore power and run a full heat and cool cycle, confirming proper sequencing and no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive despite good incoming power.
  • No ignition or blower sequence on a call for heat.
  • Fault/error codes on the board's diagnostic LED.
  • Visible burnt traces, scorching, or corrosion on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210SRCA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210SRCA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210SRCA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online