Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS210SRAA0AAAA — Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS210SRAA0AAAA — Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for ICP / Tempstar / Heil gas furnaces. The board is the brain of the furnace — it manages the ignition sequence, blower and inducer timing, safety-limit and pressure-switch monitoring, flame sensing, and thermostat communication. The kit includes the replacement board and mounting/connection components needed for installation. When a control board fails, the furnace may be completely unresponsive, fail to start the inducer or igniter, lock out on a fault, or run the blower continuously. Common failure causes include power surges, overheating, cracked solder joints, and burned relay contacts on the board itself.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Function Ignition, blower & inducer timing, safety monitoring
Application Gas Furnace
Brand ICP / Tempstar / Heil
Fit OEM Replacement

Compatibility

Fits ICP, Tempstar, Heil, Comfortmaker, and Arcoaire gas furnaces that use the 1183618 control board kit, including model RGS210SRAA0AAAA. Match the OEM board part number exactly before ordering, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every wire connection and connector position on the old board before disconnecting.
  4. Remove — Unplug all harnesses and spade terminals, then unscrew the old board from its standoffs.
  5. Install — Mount the new board, transfer the wiring exactly per your photo, and confirm all connectors are fully seated.
  6. Test — Restore power and run a full heat cycle, verifying the inducer, igniter, flame proof, and blower sequence correctly.

Signs You Need a Replacement

  • Furnace completely unresponsive with no LED diagnostic activity
  • No inducer, igniter, or blower operation on a heat call
  • Repeated lockouts or erratic fault codes
  • Visible burn marks, corrosion, or damaged relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210SRAA0AAAA — Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210SRAA0AAAA — Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210SRAA0AAAA — Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.