Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS210SFAA0AAAA — 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS210SFAA0AAAA — 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM furnace control board kit, OEM part number 1183618, for the ICP / Tempstar / Heil RGS210SFAA0AAAA gas furnace. The integrated furnace control board is the brain of the appliance: it sequences the entire heating cycle, energizing the inducer, proving pressure switches, firing the igniter, opening the gas valve, monitoring flame, and timing the blower on and off. It also manages safety lockouts and flashes diagnostic fault codes via its onboard LED. Control boards fail from heat stress, voltage surges, corroded relays, and cracked solder joints. When the board fails you typically get a completely dead furnace, a unit stuck on the blower, an inducer that won't start, or a steady or erratic diagnostic LED. This kit includes the replacement board and the hardware needed to install it.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Function Ignition sequencing, blower timing, diagnostics
Diagnostics Onboard LED fault codes
Brand ICP / Tempstar / Heil

Compatibility

Fits the ICP RGS210SFAA0AAAA and the ICP-built Tempstar, Heil, and Comfortmaker furnaces that specify control board kit 1183618. Because boards are revision-specific, confirm the printed OEM number on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph every harness connector and wire location on the old board before unplugging anything.
  4. Remove — Unplug each connector, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, then transfer each connector to the matching terminal exactly as photographed; set any DIP switches to match the original.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition sequence, blower timing, and a normal diagnostic LED.

Signs You Need a Replacement

  • Completely dead furnace with no response to a call for heat.
  • Diagnostic LED that is off, stuck on, or flashing an internal control fault code.
  • Inducer, igniter, or blower that won't energize even with good components.
  • Visible burned spots, cracked solder, or scorched relays on the board.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210SFAA0AAAA — 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210SFAA0AAAA — 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210SFAA0AAAA — 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online