Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS210LRAA0AAAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS210LRAA0AAAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part #1183618) is the brain of the ICP/Heil/Tempstar RGS210LRAA0AAAA gas furnace. It sequences the entire heat cycle — reading the thermostat call, proving the inducer and pressure switch, energizing the igniter, opening the gas valve, monitoring flame, and timing the blower on and off delays. When the board fails, the furnace may go dead, lock out, short-cycle, or run the blower continuously. This factory kit includes the board matched to the furnace's wiring harness and software so ignition and safety timing behave exactly as designed. Replacing a degraded board restores reliable, code-correct furnace operation.

Specifications

Spec Value
Part Number 1183618
Part Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Function Ignition, blower & safety timing control
Fits Model RGS210LRAA0AAAA
Fit OEM

Compatibility

Designed for the ICP family RGS210LRAA0AAAA gas furnace and its Heil, Tempstar, and Comfortmaker equivalents. Match the board number printed on your existing control and confirm the furnace model before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power to the furnace and verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire connection and label terminals before disconnecting.
  4. Remove — Unplug the harnesses, release the board standoffs/screws, and lift out the old control.
  5. Install — Mount the new board, reconnect each harness per your photo, and set any DIP switches to match the original.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition and blower timing.

Signs You Need a Replacement

  • Furnace completely dead with no response to a thermostat call
  • Repeated ignition lockouts or error/diagnostic LED fault codes
  • Blower runs constantly or never starts
  • Visible burn marks, scorched relays, or corrosion on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210LRAA0AAAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210LRAA0AAAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210LRAA0AAAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera