This is a genuine OEM control board kit (Part No. 1183618) for the ICP / Tempstar / Heil RGS210LEEA0AAAA. The integrated furnace control board is the brain of the system — it sequences ignition, monitors the flame sensor and safety limits, controls the inducer and blower motors, and manages the 24-volt signals to and from the thermostat. The kit includes the board and the hardware needed for a complete swap. Control boards typically fail from voltage surges, overheating, corroded relays, or cracked solder joints, producing symptoms that range from a completely dead furnace to erratic blower operation and repeated lockouts. Replacing the board with the correct OEM kit restores proper ignition sequencing and safety control.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Function Ignition, blower, inducer & safety sequencing
Fit OEM Replacement Kit

Compatibility

Supplied as the factory replacement kit for the ICP RGS210LEEA0AAAA furnace. It also fits compatible Tempstar, Heil, and Comfortmaker furnaces that specify the 1183618 control board kit. Match the OEM part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the furnace control-compartment panel to expose the existing board.
  3. Document — Photograph every wire harness and plug location before disconnecting — connector positions are critical.
  4. Remove — Unplug all harnesses, remove the mounting screws or standoffs, and lift out the old board.
  5. Install — Mount the new board from the kit and reconnect each harness exactly per your photos.
  6. Test — Restore power, set the thermostat to heat, and verify a full ignition, flame-proving, and blower sequence.

Signs You Need a Replacement

  • Furnace is completely dead with no response to a heat call.
  • Repeated lockouts or rapid blinking diagnostic LED error codes.
  • Blower or inducer runs continuously or won't start.
  • Visible burnt spots, scorched relays, or a burnt-electronics smell on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210LEEA0AAAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210LEEA0AAAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210LEEA0AAAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online