Overview

Genuine OEM control board kit (ICP part 1183618) for the ICP/Tempstar/Heil RGS210HFCA0AAAA furnace. The integrated furnace control board is the brain of the unit — it manages the ignition sequence, sequences the inducer and blower motors, monitors safety circuits (limits, pressure switch, flame sense), and times each stage of the heat cycle. When the board fails, symptoms range from no response on a call for heat to erratic blower behavior, repeated lockouts, or fault codes flashed on the diagnostic LED. This kit includes the replacement board for a direct swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated furnace control board kit
Brand ICP
Application Gas furnace control
Diagnostics On-board fault LED

Compatibility

Designed for the ICP/Tempstar/Heil RGS210HFCA0AAAA furnace. Match the OEM part number 1183618 and confirm the connector layout against your existing board before installing — control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph every harness plug and terminal on the old board before disconnecting.
  4. Remove — Unplug each connector, release the board standoffs/screws, and lift the old board out.
  5. Install — Mount the new board and reconnect every harness to the matching connector per your photo; confirm any DIP switch or jumper settings match the original.
  6. Test — Restore power, call for heat, and verify the full ignition and blower sequence; check the diagnostic LED for normal status.

Signs You Need a Replacement

  • No response from the furnace on a valid call for heat.
  • Diagnostic LED flashing a hard-fault or board-failure code.
  • Blower or inducer running erratically or failing to sequence.
  • Repeated lockouts with all sensors and safeties confirmed good.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS210HFCA0AAAA — Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS210HFCA0AAAA — Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS210HFCA0AAAA — Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.