Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS180STAA0AAAA – Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS180STAA0AAAA – Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM control board kit (part number 1183618, KIT CONTROL BOARD) for the ICP Tempstar Heil RGS180STAA0AAAA gas furnace. The control board is the brain of the furnace — it manages the ignition sequence, sequences the inducer and blower motors, monitors safety circuits such as limits and pressure switches, and flashes diagnostic fault codes. When the board fails you may see no response on a call for heat, erratic blower or inducer behavior, blank or constantly flashing diagnostic LEDs, or burned/scorched traces and relays on the board itself.

Specifications

Spec Value
Part Number 1183618
Description Kit Control Board
Type Integrated Furnace Ignition Control Board
Brand ICP (Tempstar / Heil)
Fits Model RGS180STAA0AAAA
Fitment OEM Direct Replacement Kit

Compatibility

This control board kit is the OEM replacement for the ICP Tempstar Heil RGS180STAA0AAAA furnace and is supplied as a kit with the hardware needed for installation. ICP builds equipment under the Tempstar, Heil, and Comfortmaker brands, so this board may also fit equivalent models. Always confirm the existing board part number before ordering.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch or breaker and verify zero voltage with a multimeter.
  2. Access – Remove the furnace control/blower compartment access panel.
  3. Document – Photograph every wire and connector on the board before removing anything; the wiring is plug-and-screw specific.
  4. Remove – Disconnect all harnesses and low-voltage leads, remove the board mounting screws, and lift out the old board.
  5. Install – Mount the new board on the original standoffs and reconnect each wire and harness exactly per your photos.
  6. Test – Restore power, run a full heat cycle, and confirm proper ignition, blower, and inducer operation with no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a call for heat.
  • Blank, dead, or continuously flashing diagnostic LED.
  • Erratic blower or inducer operation, or random shutdowns.
  • Visible burn marks, corrosion, or failed relays on the board.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180STAA0AAAA – Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180STAA0AAAA – Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180STAA0AAAA – Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online