Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS180LTEA0AAAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS180LTEA0AAAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM furnace control board kit (Part #1183618) is the integrated ignition control ("brain") for the ICP / Tempstar / Heil RGS180LTEA0AAAA gas furnace. The board sequences the entire heating cycle: it runs the inducer, proves the pressure switch, energizes the igniter, opens the gas valve, monitors flame, and times the blower on and off. It also manages safety lockouts and flashes diagnostic fault codes. A failed board commonly causes a dead furnace, no inducer or blower operation, repeated lockouts, or erratic cycling. The kit includes mounting hardware for a complete, straightforward replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Line Voltage 120V
Function Ignition, blower & safety control with diagnostics
Fitment OEM

Compatibility

Built for the ICP RGS180LTEA0AAAA and shared across compatible ICP-family furnaces sold as Tempstar, Heil, Comfortmaker, and Arcoaire. Confirm the board part number and connector layout against your original before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas; verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment door.
  3. Document — Photograph every connector and wire harness on the existing board.
  4. Remove — Unplug all harnesses and remove the mounting screws holding the old board.
  5. Install — Mount the new board with the included hardware and reconnect each harness exactly per your photos.
  6. Test — Restore gas and power, call for heat, and confirm a complete, fault-free heating cycle.

Signs You Need a Replacement

  • Furnace completely dead with no inducer or blower response
  • Repeated lockouts or diagnostic LED fault codes pointing to the control
  • Blower runs continuously or won't start on a heat call
  • Visible burnt traces, relays, or scorched connectors on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180LTEA0AAAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180LTEA0AAAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180LTEA0AAAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online