Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS180LTCA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS180LTCA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the factory-specified integrated furnace control (IFC) for the ICP / Tempstar / Heil RGS180LTCA0AAAA gas furnace. The control board is the brain of the furnace — it sequences the inducer, igniter, gas valve, and blower, monitors the safety circuit, and flashes diagnostic fault codes. Because it manages line and low-voltage circuits and endures constant thermal cycling, a failed board can cause anything from intermittent no-heat to a furnace that won't respond at all.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition sequencing, blower control, safety monitoring, diagnostics
Kit Contents Control board with mounting hardware/instructions
Fit OEM direct replacement

Compatibility

Direct OEM replacement kit for the ICP / Tempstar / Heil RGS180LTCA0AAAA furnace. Control boards are model-specific — verify the OEM part number 1183618 and the connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower service panel.
  3. Document — Photograph every harness plug and terminal, and note any DIP-switch or jumper settings before disconnecting.
  4. Remove — Unplug each connector, remove the board mounting screws, and lift the old board off its standoffs.
  5. Install — Mount the new board, transfer any jumpers/DIP settings, and reconnect each harness to the matching plug per your photo.
  6. Test — Restore power, call for heat, and confirm a full ignition sequence with a normal status LED and no fault codes.

Signs You Need a Replacement

  • No response from the furnace — inducer, igniter, and blower all stay dead on a heat call
  • Status LED off, or flashing a hard-fault / internal-control code
  • Intermittent operation, random lockouts, or relays that won't energize
  • Visible burn marks, corrosion, or a cracked board / failed relay

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180LTCA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180LTCA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180LTCA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online