Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS180LSEA0AAAA — 24V OEM | Ships Today
ICP

ICP Furnace Control Board Kit for RGS180LSEA0AAAA — 24V OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM Control Board Kit (part #1183618) for the ICP / Tempstar / Heil RGS180LSEA0AAAA gas furnace. The integrated furnace control board is the brain of the unit — it sequences ignition, monitors safety limits and flame, controls the inducer and blower motors, and manages the 24V thermostat call. When this board fails, the furnace typically will not start, locks out after a few ignition attempts, or runs the blower continuously. Installing the correct OEM board restores reliable, code-compliant operation without guesswork. This is supplied as a kit, so it includes the board and the hardware needed for a direct replacement of the original.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Fits Model RGS180LSEA0AAAA
Fitment OEM Direct Replacement

Compatibility

Designed for the ICP Tempstar Heil RGS180LSEA0AAAA furnace. ICP manufactures under several brand names, so this board is also found in matching Comfortmaker and Day & Night equipment that uses the same control. Always confirm the printed control number on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting anything.
  4. Remove — Unplug the wire harnesses, release the board mounting standoffs/screws, and lift out the old control.
  5. Install — Mount the new board on the same standoffs and reconnect each harness exactly per your photos.
  6. Test — Restore power, initiate a heat call, and confirm proper ignition, flame sense, and blower sequencing.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out after repeated ignition attempts.
  • Blower runs constantly or never engages on a heat call.
  • No response to the thermostat despite 24V present at the board.
  • Visible burnt traces, swollen relays, or a cracked board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180LSEA0AAAA — 24V OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180LSEA0AAAA — 24V OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180LSEA0AAAA — 24V OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online