Overview

This genuine OEM control board kit, part number 1183618, is the integrated furnace control (IFC) for the ICP / Tempstar / Heil RGS180LSCA0AAAA gas furnace. The control board manages the ignition sequence, gas valve, blower and inducer timing, safety lockouts, and diagnostic fault codes. A failed board is one of the most common no-heat causes — symptoms include a dead furnace with no LED, a blower or inducer that will not start, erratic cycling, or a flashing diagnostic code that points to the control itself.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board (Integrated Furnace Control)
Type Furnace control board kit
Brand ICP / Tempstar / Heil
Fit OEM direct replacement
Application Gas furnace ignition & blower control

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil model RGS180LSCA0AAAA gas furnace. This is a kit, so confirm the included mounting hardware/harness matches your unit, and verify part number 1183618 on the furnace parts breakdown before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower/control service panel.
  3. Document — Photograph every wire and connector on the old board before disconnecting.
  4. Remove — Unplug all harnesses, release the board standoffs/screws, and remove the old control.
  5. Install — Mount the new 1183618 board on the kit standoffs and reconnect every harness exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm correct ignition, blower, and a clear (no-fault) diagnostic LED.

Signs You Need a Replacement

  • Furnace completely dead with no control LED
  • Inducer or blower will not energize on a call for heat
  • Persistent hard-lockout or a diagnostic code pointing to the control
  • Burnt traces, scorched relay, or corrosion visible on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180LSCA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180LSCA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180LSCA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart