Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS180LRCA0AAAA — OEM Part 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS180LRCA0AAAA — OEM Part 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) that runs the entire ignition and safety sequence on the ICP / Tempstar / Heil RGS180LRCA0AAAA gas furnace. It manages the inducer, igniter, gas valve, and blower timing, monitors the flame sensor and safety limits, and flashes diagnostic fault codes through its onboard LED. When the board fails, the furnace may be completely dead, stuck on continuous blower, locked out on ignition, or throwing erratic fault codes. The kit ships with the matched board and mounting hardware for a direct factory replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Function Ignition, safety, blower & inducer control
Diagnostics Onboard LED fault codes
Brand ICP / Tempstar / Heil
Fits Model RGS180LRCA0AAAA
Fitment OEM exact replacement

Compatibility

Built for the ICP Tempstar Heil RGS180LRCA0AAAA and shared-platform furnaces that use this integrated control. Match the original board part number and connector layout before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph every harness connector and the board's mounting position before unplugging anything.
  4. Remove — Unplug each connector, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board on the supplied hardware and reconnect every harness to its matching plug per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm normal ignition, blower operation, and a steady (no-fault) status LED.

Signs You Need a Replacement

  • Furnace completely dead with no response to a heat call
  • Continuous blower operation or no blower at all
  • Repeated ignition lockouts or erratic LED fault codes
  • Visible scorching, burnt traces, or a blown relay on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180LRCA0AAAA — OEM Part 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180LRCA0AAAA — OEM Part 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180LRCA0AAAA — OEM Part 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online