This OEM control board kit (part #1183618) is the integrated furnace control (IFC) that manages the entire heating and cooling sequence on your ICP/Tempstar/Heil RGS180LFCA0AAAA gas furnace. The board sequences the inducer motor, igniter, gas valve, and blower, monitors flame sense and pressure-switch inputs, and runs onboard diagnostics with a flash-code LED. Supplied as a complete kit with the hardware and connectors needed for a direct swap. Failure symptoms include a dead furnace with no LED, erratic blower behavior, stuck-on or no-ignition sequences, and repeated fault codes that don't trace to a single component.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, blower & safety sequencing
Diagnostics Onboard LED flash codes

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil RGS180LFCA0AAAA and matched Comfortmaker, Arcoaire, and KeepRite furnaces specifying control kit 1183618. Match the board layout and connector pinout to your existing control before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment door.
  3. Document — Photograph every wire harness and terminal connection on the old board.
  4. Remove — Unplug the harnesses, release the board standoffs, and lift out the old control.
  5. Install — Mount the new board, transfer connectors one at a time, and set any DIP/jumper options to match.
  6. Test — Restore power, run a full heat and cool cycle, and confirm the LED shows normal operation with no fault codes.

Signs You Need a Replacement

  • No power or no diagnostic LED at the board
  • Furnace won't sequence through ignition or blower stages
  • Blower runs constantly or won't start
  • Persistent or random fault codes after other parts test good

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180LFCA0AAAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180LFCA0AAAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180LFCA0AAAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online