The OEM Control Board Kit (part number 1183618) is the integrated furnace control (IFC) that runs the entire heating sequence in your ICP / Tempstar / Heil RGS180LEEA0AAAA furnace. This board manages the ignition sequence, inducer and blower timing, gas valve operation, and all safety interlocks, while monitoring flame sensing and pressure switches. When the control board fails, the furnace may not respond to the thermostat, the inducer or blower may run continuously or not at all, ignition may never initiate, or the unit may repeatedly lock out. Because the board interprets every safety input, a faulty IFC can shut the system down entirely. This genuine OEM kit includes the board and the hardware needed for a clean, code-correct replacement.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC)
Control Voltage 24 VAC
Brand ICP (Tempstar / Heil)
Fitment OEM Direct Replacement Kit

Compatibility

This control board kit is a direct OEM fit for the ICP / Tempstar / Heil RGS180LEEA0AAAA furnace and the related RGS-series control platform. Match the board's part number and connector layout to your existing control before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas supply. Verify zero voltage with a multimeter before working.
  2. Access — Remove the furnace blower-compartment service panel to expose the control board.
  3. Document — Photograph every connector, harness plug, and the dip-switch/jumper settings before disconnecting.
  4. Remove — Unplug each harness, release the board standoffs or mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer any required jumper/dip-switch settings, and reconnect each harness to its matching plug per your photos.
  6. Test — Restore gas and power, run a full heat cycle, and confirm correct ignition, blower timing, and no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace does not respond to the thermostat call for heat
  • Blower or inducer runs constantly or never starts
  • Repeated lockouts or erratic diagnostic fault codes
  • Visible burnt traces, scorching, or failed relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180LEEA0AAAA — OEM Part 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180LEEA0AAAA — OEM Part 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180LEEA0AAAA — OEM Part 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.