Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS180LDEA0AAAA – OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS180LDEA0AAAA – OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM integrated furnace control board kit (Part No. 1183618) is the brain of the ICP/Tempstar/Heil RGS180LDEA0AAAA gas furnace. It sequences ignition, manages the inducer and blower timing, monitors flame and limit safeties, and runs onboard diagnostics via its LED fault codes. Supplied as a complete kit with mounting hardware and instructions, it replaces a board that has failed due to power surges, heat stress, cracked solder joints, or a blown onboard fuse. A failed control board typically shows as no response on a call for heat, blower or inducer that won't cycle correctly, or a board that no longer flashes diagnostic codes.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Includes Board, mounting hardware, instructions

Compatibility

OEM kit for the ICP RGS180LDEA0AAAA furnace and equivalent units under the Tempstar, Heil, and Comfortmaker brands. Verify the board's connector layout and part number against your existing control before installing.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access – Remove the control-compartment door.
  3. Document – Photograph every wire harness and terminal before disconnecting.
  4. Remove – Unplug the harnesses, release the standoffs, and lift out the old board.
  5. Install – Mount the new board on the included hardware and reconnect each harness exactly per your photo.
  6. Test – Restore power, call for heat, and confirm the full ignition-to-blower sequence and clear diagnostic LED.

Signs You Need a Replacement

  • No response from the furnace on a heat call
  • Inducer or blower fails to start or runs continuously
  • No diagnostic LED, or erratic/garbled fault codes
  • Visible burn marks, swollen relay, or blown onboard fuse

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180LDEA0AAAA – OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180LDEA0AAAA – OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180LDEA0AAAA – OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.