Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS180HFEA0AAAA — OEM Part 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS180HFEA0AAAA — OEM Part 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the integrated furnace control for the ICP / Tempstar / Heil RGS180HFEA0AAAA. The board is the brain of the furnace: it sequences the ignition cycle, monitors the pressure switch and limit safeties, controls the inducer and blower motors, and manages timing and flame proving. When a control board fails you may see no response to a thermostat call, blower motors that won't start or won't stop, repeated lockouts, or fault codes flashed on the diagnostic LED. The kit supplies the correct OEM board so the furnace returns to safe, factory-spec operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Functions Ignition Sequencing, Blower & Inducer Control, Safety Monitoring
Diagnostics Onboard LED Fault Codes
Fitment OEM Exact-Fit Kit

Compatibility

Built for the ICP / Tempstar / Heil RGS180HFEA0AAAA gas furnace. Verify the existing board part number and connector layout against the kit before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off gas; verify zero voltage with a multimeter.
  2. Access — Remove the control / blower compartment panel.
  3. Document — Photograph every wire harness and connector position before disconnecting.
  4. Remove — Unplug each connector, unfasten the old board, and note any jumper or DIP settings.
  5. Install — Mount the new board, transfer settings, and reconnect every harness per your photo.
  6. Test — Restore gas and power, run a full heating cycle, and confirm the diagnostic LED shows normal operation.

Signs You Need a Replacement

  • No response to a thermostat heat call
  • Blower or inducer that won't start or won't shut off
  • Repeated ignition lockouts or error codes on the LED
  • Visible burn marks, cracked traces, or scorched relays on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180HFEA0AAAA — OEM Part 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180HFEA0AAAA — OEM Part 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180HFEA0AAAA — OEM Part 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart