This OEM control board kit (ICP part number 1183618, "KIT CONTROL BOARD") is the integrated furnace control (IFC) for the ICP/Tempstar/Heil RGS180HFAA0AAAA gas furnace. It is the furnace's brain: it sequences the inducer, igniter, gas valve, and blower; monitors safety inputs such as the pressure switch and flame sensor; and manages ignition timing and lockout logic. Supplied as a complete kit so you have the board and any required mounting hardware for a clean replacement. A failed board causes no-heat calls, erratic blower behavior, or fault-code lockouts.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V control / 120V line
Fitment OEM, model-specific

Compatibility

Designed for the ICP/Tempstar/Heil RGS180HFAA0AAAA gas furnace and related RGS180 series units calling out kit 1183618. Verify the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph every wire and connector on the board before disconnecting anything.
  4. Remove — Unplug all harness connectors and line-voltage leads, then unscrew the old board from its standoffs.
  5. Install — Mount the new board, then reconnect each connector and lead exactly per your photos.
  6. Test — Restore gas and power and run a full heat cycle, confirming proper inducer, ignition, gas-valve, and blower sequencing with no fault codes.

Signs You Need a Replacement

  • No response on a heat call or repeated ignition lockouts
  • Blower runs constantly or won't start
  • Diagnostic LED flashes a hard-fault / board failure code
  • Visible scorching, corrosion, or failed relays on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180HFAA0AAAA — OEM Ignition Control 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180HFAA0AAAA — OEM Ignition Control 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180HFAA0AAAA — OEM Ignition Control 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.