Overview

This OEM control board kit (part number 1183618, "KIT CONTROL BOARD") is the integrated furnace control for the ICP / Heil / Tempstar RGS180HDCA0AAAA gas furnace. The board manages the ignition sequence, blower and inducer timing, safety lockouts, and thermostat communication. When it fails, the furnace may not respond to a heat call, may short-cycle, may run the blower continuously, or may lock out with diagnostic LED fault codes. As a complete OEM kit it ships with the correct firmware/timings and mounting hardware so the sequence of operation matches the factory specification.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC)
Brand ICP (Heil / Tempstar)
Fits Model RGS180HDCA0AAAA
Fit OEM Direct Replacement

Compatibility

Built for the ICP / Heil / Tempstar RGS180HDCA0AAAA furnace and related International Comfort Products gas furnaces using this control kit. Verify part number 1183618 against your furnace's rating plate / parts list before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/service panel.
  3. Document — Photograph every wire and connector on the existing board before disconnecting anything.
  4. Remove — Label and unplug each harness, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new 1183618 board, transfer any jumpers/links, and reconnect every harness exactly per your photos.
  6. Test — Restore gas and power, run a full heat cycle, and confirm correct inducer, ignition, and blower timing with no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a call for heat
  • Blinking diagnostic LED fault codes pointing to the control
  • Short-cycling or blower running continuously
  • Visible burnt traces, scorch marks, or a blown onboard fuse/relay

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS180HDCA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS180HDCA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS180HDCA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.