This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) that runs the entire heating sequence on the ICP / Tempstar / Heil RGS150SECA0AAAA. It manages inducer startup, pressure-switch verification, hot surface igniter timing, gas valve operation, flame sensing, and blower on/off delays, while monitoring safety limits and reporting fault codes through its diagnostic LED. As a kit, it ships with the mounting and connector hardware needed for a clean swap. Control boards fail from power surges, heat stress, corroded relays, and burnt traces around the gas valve and igniter terminals — and a failed board can stop heating entirely, cause erratic blower behavior, or trip random lockouts.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Functions Ignition, Blower, Flame Sense, Safety Limits
Fit OEM Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS150SECA0AAAA furnace and related ICP-family units that originally used control board 1183618. Verify the board layout and connector pinout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower/control compartment panel.
  3. Document — Photograph every connector and wire location before removing anything.
  4. Remove — Unplug all harness connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board from the kit and reconnect every harness exactly per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower timing, and a steady status LED.

Signs You Need a Replacement

  • No response on a call for heat (no inducer, no igniter)
  • Blower runs constantly or won't start
  • Random lockouts or shifting fault codes
  • Visible burnt traces, scorched relays, or melted connectors

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150SECA0AAAA — OEM Integrated Module | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150SECA0AAAA — OEM Integrated Module | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150SECA0AAAA — OEM Integrated Module | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.